CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved)

Here are optional user solutions for the Renault can clip v159 was connected to PC, detected with the number 926 573 and recognized ” RLT2002 PROBE”, but CLIP popped an error message- “Failure of the reservation of the probe. Try it again and contact technical assistance in case of another failure” .

CAN Clip v159 RLT 2002 Probe 1 600x345 - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved) - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved) CAN Clip v159 RLT 2002 Probe 2 600x416 - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved) - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved)

CAN CLIP is connecting to the laptop and the car

CAN and ISO LED light up

CAN Clip v159 RLT 2002 Probe 3 600x446 - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved) - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved)

CAN CLIP is connecting to the car

ISO LED light up

CAN CLIP is connecting to the laptop

CAN LED light up

CAN Clip v159 RLT 2002 Probe 5 600x458 - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved) - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved)

 

–> First, you can try the easy solution:

check in device manager, it is alliance B

yes works with both but not work on both on same partition so better to install on different computers or use the boot it.

best to install Clip first and let that update the firmware and then install Consult 3 scan tool  and enter serial you saw in Clip software , as above.

I have made it many many times .

 

–> Still not work??

That is….

You don’t have a real CAN CLIP RLT2002 PROBE
You have a hybrid of Alliance VI in CAN CLIP case
It will work good don’t bougter of it
It will install only one driver instead of 4 as for real CAN CLIP Probe
And much more of this it is working wit Consult III software till 9.21.02 as well

You can check and see the difference between this two kind of Chinese clones:

 

real CAN CLIP PROBE clone – RLT2002

clip 1 450x600 - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved) - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved)

 

Allianbce hybrid Can Clip sonde – 926573

clip 2 600x400 - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved) - CAN Clip v159 RLT 2002 Probe “Failure of reservation of probe” (solved)