Xentry PassThru – Questions and Answers

July 11, 2018 sales 0

There are a lot of Xentry PassThru questions frequently asked and answers given by users and folks in http://mhhauto.com/ Hope it helps.   All PassThru versions works as good and as same as SDconnect C4 units? – for xentry, i check all diag files are identical with open shell. – Continue Reading →

201803-sd-c4-software-1-1

How to use Xentry/DAS passthru j2534?

March 21, 2018 sales 0

What is the AVDI recognized by Xentry?  Xentry Passthru is different from from regular Xentry openshell. Xentry passthru does not use SDconnect toolkit. When you launch the program it will give you a dropdown where you can choose which J2534 device (can be found at http://www.obdexpress.co.uk/) Continue Reading →

09-2017_xentry_expire_1

(Solved) 09.2017 Xentry/DAS Expire

February 8, 2018 sales 0

  09.2017 Xentry/DAS Expire Error Message and Solution:   Xentry/DAS Expire Error: La validata dell’attuale versione dei dati scadra dal 2018/02/21. installare una versione dei dati attuale. Error message in English: The validated current version of the data w Continue Reading →

Pedal-Curve-2

How MB Variant coding tweaks & throttle delay

November 26, 2017 sales 0

[[I am copying this post from the one I made on MBworld as well, I figure both forums should see it, especially considering MrScott belongs to this one!]] This post assumes you have some knowledge of the software used. I’m not entirely comfortable making a full walk-through for beginners, Continue Reading →

DAS-CAL-830-ERROR-1

How to solve SDconnect DAS CAL error number 830

November 6, 2017 sales 0

Issue from sd connect c4 user: Hello  i have installed Xentry/Das. After i made xentry and das registration i have error connection. I have try many bin files but the same. When SDconnect C4recognise car voltage, can’t recognise vin so doesn’t make diagnosis ! Photos of error message:   D Continue Reading →

wis-is-not-available-on-this-system-solution

WIS Is Not Available On DAS!

October 23, 2017 sales 0

  One issue from user:WIS from DAS not run!!!   I installed WIS Standanlone 07/16 on XDOS 09/16. WIS works good from desktop and from Xentry, but when i try start WIS from DAS i have error: “wis is not available on this system”     Reply:   WIS Standalone wor Continue Reading →

v2017.07-mb-sd-software-hdd-1

How to use Xentry/DAS Developer Mode

August 28, 2017 sales 0

  MB Star Diagnosis Xentry/DAS Developer Mode User Manual:   What you need for Xentry/DAS Developer Mode? When & why you should use Developer Mode? How to use Developer Mode step by step?     THE MOST IMPORTANT NOTE: you are trying on your own risk!!!!!!!!   Be very c Continue Reading →