MB sdconnect C4 update firmware in mux

This document provides simple step-by-step instructions for updating the kernel software (operating system) on your Star Diagnosis SD connect multiplexer.
The kernel update of the SDconnect is similar to a regular software update via the Star Diagnosis system.
FYI, most people buy sdconnect C4 plus one used Dell D630 with pre-installed software and authorized files. Details:
http://www.obdexpress.co.uk/wholesale/mb-sd-connect-compact-4-star-diagnosis-hdd-d.html

Step 1 Introduction
Step 2 Connecting the SDconnect to the Star Diagnosis system.
Step 3 SDnetControl
Step 4 Software update
Step 5 Completing the installation
Step 6 Checking the installed software

Step 1 Introduction
1)Check battery if needed (only if related message is shown in the display)
When working on the vehicle or using an external power supply, the message “! Batteries cannot be charged!” may sometimes appear on the SDconnect display:
This may be related to tarnishing, crystal formation, or corrosion on the battery contacts or leaking batteries:

leaking batteries 01 - MB sdconnect C4 update firmware in mux -

Since the external power supply is extremely important for the update process, the batteries should be checked for the above-mentioned indications by removing the side panel on the SDconnect (see details on how to install batteries at
http://www.obdexpress.co.uk/upload/service/steps-for-installing-battery.pdf ).
• If the batteries are contaminated, you can do the following:
– Clean or polish the battery contacts and re-check the battery function.
– Exchange the batteries if necessary (see SDconnect manual, chapter 2.3.2, for notes on batteries)
• After checking the batteries, you can continue with the next step.

2)Closing the Xentry Diagnostics/Xentry DAS diagnostics application
When accessing a vehicle in Xentry Diagnostics or Xentry DAS, the following message appears:
Update SDconnect 02 - MB sdconnect C4 update firmware in mux -
Please exit the diagnostic application Xentry Diagnostics or Xentry DAS correctly and follow the next steps.

Step 2 Connecting the SDconnect to the Star Diagnosis system
Connect the SDconnect to the Star Diagnosis system with the green cable.
The SDconnect will be automatically selected and appear in the deskband on the Star Diagnosis
system:
update SDconnect 03 - MB sdconnect C4 update firmware in mux -
Step 3 SDnetControl
Start SDnetControl by clicking the deskband
1)Go to the “Connections” tab.
2) Check whether automatic selection via the cable connection is active:
SDnect control 04 - MB sdconnect C4 update firmware in mux -
2)Go to the “Configuration” tab, and confirm the warning with “Yes”:
Update SDconnect 05 - MB sdconnect C4 update firmware in mux -
Step 4 Software update
Go to the “MUX” tab in SDnetControl.
Click on the “Software update” button.
update mux 06 - MB sdconnect C4 update firmware in mux -
The “SDconnect Toolkit Administration” program will start.
1)Go to the “Software update” tab in the SDconnect Toolkit.
2)Your SDconnect is already selected on the left-hand side.
3)Select the “Software update” packet under “Files for software update”.
4)Click “Start” to start the process.
SDconnect software update 07 - MB sdconnect C4 update firmware in mux -
The update process will start. This takes approx. 4 minutes.

Step 5 Completing the installation
Confirm the successful completion of the update.
After a successful update, a message indicating the successful update completion appears.
Confirm the message by clicking “OK”.
confirm update 08 - MB sdconnect C4 update firmware in mux -
Update not successful
If the update was not successful, the message “The software update was aborted. Please repeat theupdate process” will appear.
Confirm this message by clicking “OK”. Check the SDconnect batteries if necessary and repeat the update process.
update SDconnect not successful 09 - MB sdconnect C4 update firmware in mux -
Step 6 Checking the installed software
Go to the “Information” tab in SDconnect Toolkit
Select your SDconnect on the left-hand side.
• Check the information under “Software versions” at the right:
The versions of the Linux OS and the CommandServer must be at least 2:0:xxxxxx.
check installed software 10 - MB sdconnect C4 update firmware in mux -
The SD connect software update is complete. The green cable can be removed.